Package | hl7.terminology |
Type | CodeSystem |
Id | Id |
FHIR Version | R5 |
Source | http://terminology.hl7.org/https://build.fhir.org/ig/HL7/UTG/CodeSystem-v2-0357.html |
Url | http://terminology.hl7.org/CodeSystem/v2-0357 |
Version | 2.0.0 |
Status | active |
Date | 2019-12-01 |
Name | MessageErrorCondition |
Title | messageErrorCondition |
Experimental | False |
Realm | uv |
Authority | hl7 |
Description | HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging. |
Purpose | Underlying Master Code System for V2 table 0357 (Message Error Condition Codes) |
Copyright | This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html |
Content | complete |
valueSet | http://terminology.hl7.org/ValueSet/v2-0357 |
ValueSet | |
v2-0357 | hl7VS-messageErrorConditionCodes |
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: CodeSystem v2-0357
Properties
This code system defines the following properties for its concepts
Name | Code | URI | Type | Description |
status | status | http://terminology.hl7.org/CodeSystem/utg-concept-properties#status | code | Status of the concept |
deprecated | deprecated | http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated | code | Version of HL7 in which the code was deprecated |
V2 Concept Comment | v2-concComment | http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment | string | V2 Concept Comment |
V2 Concept Comment As Published | v2-concCommentAsPub | http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub | string | V2 Concept Comment As Published |
Concepts
This case-sensitive code system http://terminology.hl7.org/CodeSystem/v2-0357
defines the following codes in a Is-A hierarchy:
{
"resourceType" : "CodeSystem",
"id" : "v2-0357",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem v2-0357</b></p><a name=\"v2-0357\"> </a><a name=\"hcv2-0357\"> </a><a name=\"v2-0357-en-US\"> </a><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Name</b></td><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>V2 Concept Comment</td><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>V2 Concept Comment As Published</td><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>string</td><td>V2 Concept Comment As Published</td></tr></table><p><b>Concepts</b></p><p>This case-sensitive code system <code>http://terminology.hl7.org/CodeSystem/v2-0357</code> defines the following codes in a Is-A hierarchy:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td><td><b>Deutsch (German, de)</b></td></tr><tr><td style=\"white-space:nowrap\">0<a name=\"v2-0357-0\"> </a></td><td>Message accepted</td><td>Message accepted</td><td>Success. Optional, as the AA conveys success. Used for systems that must always return a status code.</td><td>Success. Optional, as the AA conveys success. Used for systems that must always return a status code.</td><td>Nachricht akzeptiert</td></tr><tr><td style=\"white-space:nowrap\">100<a name=\"v2-0357-100\"> </a></td><td>Segment sequence error</td><td>Segment sequence error</td><td>Error: The message segments were not in the proper order, or required segments are missing.</td><td>Error: The message segments were not in the proper order, or required segments are missing.</td><td>Fehler in der Segmentreihenfolge</td></tr><tr><td style=\"white-space:nowrap\">101<a name=\"v2-0357-101\"> </a></td><td>Required field missing</td><td>Required field missing</td><td>Error: A required field is missing from a segment</td><td>Error: A required field is missing from a segment</td><td>erforderliches Feld leer</td></tr><tr><td style=\"white-space:nowrap\">102<a name=\"v2-0357-102\"> </a></td><td>Data type error</td><td>Data type error</td><td>Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".</td><td>Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".</td><td>Datentypfehler</td></tr><tr><td style=\"white-space:nowrap\">103<a name=\"v2-0357-103\"> </a></td><td>Table value not found</td><td>Table value not found</td><td>Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.</td><td>Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.</td><td>fehlender Eintrag in der Tabelle</td></tr><tr><td style=\"white-space:nowrap\">104<a name=\"v2-0357-104\"> </a></td><td>Value too long</td><td>Value too long</td><td>Error: a value exceeded the normative length, or the length that the application is able to safely handle.</td><td>Error: a value exceeded the normative length, or the length that the application is able to safely handle.</td><td/></tr><tr><td style=\"white-space:nowrap\">198<a name=\"v2-0357-198\"> </a></td><td>Non-Conformant Cardinality</td><td>An error has been encountered related to HL7 message content. Message is not -conformant with the applicable specificationâs (base standard, conformance profile or implementation profile) cardinality.</td><td>Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">199<a name=\"v2-0357-199\"> </a></td><td>Other HL7 Error</td><td>Any other error with the HL7 syntax that is not captured in any of the other error codes in this set.</td><td>Error</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">200<a name=\"v2-0357-200\"> </a></td><td>Unsupported message type</td><td>Unsupported message type</td><td>Rejection: The Message Type is not supported.</td><td>Rejection: The Message Type is not supported.</td><td>Nachrichtentyp wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">201<a name=\"v2-0357-201\"> </a></td><td>Unsupported event code</td><td>Unsupported event code</td><td>Rejection: The Event Code is not supported.</td><td>Rejection: The Event Code is not supported.</td><td>Ereignis wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">202<a name=\"v2-0357-202\"> </a></td><td>Unsupported processing id</td><td>Unsupported processing id</td><td>Rejection: The Processing ID is not supported.</td><td>Rejection: The Processing ID is not supported.</td><td>Processing-ID wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">203<a name=\"v2-0357-203\"> </a></td><td>Unsupported version id</td><td>Unsupported version id</td><td>Rejection: The Version ID is not supported.</td><td>Rejection: The Version ID is not supported.</td><td>Version wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">204<a name=\"v2-0357-204\"> </a></td><td>Unknown key identifier</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient.</td><td>Schlüsselwert nicht gefunden</td></tr><tr><td style=\"white-space:nowrap\">205<a name=\"v2-0357-205\"> </a></td><td>Duplicate key identifier</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.).</td><td>doppelter Schlüsselwert</td></tr><tr><td style=\"white-space:nowrap\">206<a name=\"v2-0357-206\"> </a></td><td>Application record locked</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The transaction could not be performed at the application storage level, e.g., database locked.</td><td>Datensatz durch Applikation gesperrt</td></tr><tr><td style=\"white-space:nowrap\">207<a name=\"v2-0357-207\"> </a></td><td>Application error</td><td>An application level error has occurred and the detail for that error is identified in ERR-5.</td><td>This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide.</td><td>Rejection: A catchall for internal errors not explicitly covered by other codes.</td><td>applikationsinterner Fehler</td></tr></table></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "inm"
}
],
"url" : "http://terminology.hl7.org/CodeSystem/v2-0357",
"identifier" : [
{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.18.217"
}
],
"version" : "2.0.0",
"name" : "MessageErrorCondition",
"title" : "messageErrorCondition",
"status" : "active",
"experimental" : false,
"date" : "2019-12-01",
"publisher" : "Health Level Seven International",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://hl7.org"
},
{
"system" : "email",
"value" : "hq@HL7.org"
}
]
}
],
"description" : "HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.",
"purpose" : "Underlying Master Code System for V2 table 0357 (Message Error Condition Codes)",
"copyright" : "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html",
"caseSensitive" : true,
"valueSet" : "http://terminology.hl7.org/ValueSet/v2-0357",
"hierarchyMeaning" : "is-a",
"compositional" : false,
"versionNeeded" : false,
"content" : "complete",
"property" : [
{
"code" : "status",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
"description" : "Status of the concept",
"type" : "code"
},
{
"code" : "deprecated",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
"description" : "Version of HL7 in which the code was deprecated",
"type" : "code"
},
{
"code" : "v2-concComment",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment",
"description" : "V2 Concept Comment",
"type" : "string"
},
{
"code" : "v2-concCommentAsPub",
"uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub",
"description" : "V2 Concept Comment As Published",
"type" : "string"
}
],
"concept" : [
{
"id" : "3570",
"code" : "0",
"display" : "Message accepted",
"definition" : "Message accepted",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Nachricht akzeptiert"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Success. Optional, as the AA conveys success. Used for systems that must always return a status code."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Success. Optional, as the AA conveys success. Used for systems that must always return a status code."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3571",
"code" : "100",
"display" : "Segment sequence error",
"definition" : "Segment sequence error",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Fehler in der Segmentreihenfolge"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error: The message segments were not in the proper order, or required segments are missing."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Error: The message segments were not in the proper order, or required segments are missing."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3572",
"code" : "101",
"display" : "Required field missing",
"definition" : "Required field missing",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "erforderliches Feld leer"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error: A required field is missing from a segment"
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Error: A required field is missing from a segment"
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3573",
"code" : "102",
"display" : "Data type error",
"definition" : "Data type error",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Datentypfehler"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error: The field contained data of the wrong data type, e.g., an NM field contained \"FOO\"."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Error: The field contained data of the wrong data type, e.g., an NM field contained \"FOO\"."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3574",
"code" : "103",
"display" : "Table value not found",
"definition" : "Table value not found",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "fehlender Eintrag in der Tabelle"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3575",
"code" : "104",
"display" : "Value too long",
"definition" : "Value too long",
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error: a value exceeded the normative length, or the length that the application is able to safely handle."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Error: a value exceeded the normative length, or the length that the application is able to safely handle."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3576",
"code" : "198",
"display" : "Non-Conformant Cardinality",
"definition" : "An error has been encountered related to HL7 message content. Message is not -conformant with the applicable specificationâs (base standard, conformance profile or implementation profile) cardinality.",
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message."
},
{
"code" : "status",
"valueCode" : "N"
}
]
},
{
"id" : "3577",
"code" : "199",
"display" : "Other HL7 Error",
"definition" : "Any other error with the HL7 syntax that is not captured in any of the other error codes in this set.",
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Error"
},
{
"code" : "status",
"valueCode" : "N"
}
]
},
{
"id" : "3578",
"code" : "200",
"display" : "Unsupported message type",
"definition" : "Unsupported message type",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Nachrichtentyp wird nicht unterstützt"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Rejection: The Message Type is not supported."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The Message Type is not supported."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3579",
"code" : "201",
"display" : "Unsupported event code",
"definition" : "Unsupported event code",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Ereignis wird nicht unterstützt"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Rejection: The Event Code is not supported."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The Event Code is not supported."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3580",
"code" : "202",
"display" : "Unsupported processing id",
"definition" : "Unsupported processing id",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Processing-ID wird nicht unterstützt"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Rejection: The Processing ID is not supported."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The Processing ID is not supported."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3581",
"code" : "203",
"display" : "Unsupported version id",
"definition" : "Unsupported version id",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Version wird nicht unterstützt"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "Rejection: The Version ID is not supported."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The Version ID is not supported."
},
{
"code" : "status",
"valueCode" : "A"
}
]
},
{
"id" : "3582",
"code" : "204",
"display" : "Unknown key identifier",
"definition" : "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Schlüsselwert nicht gefunden"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient."
},
{
"code" : "status",
"valueCode" : "B"
}
]
},
{
"id" : "3583",
"code" : "205",
"display" : "Duplicate key identifier",
"definition" : "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "doppelter Schlüsselwert"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.)."
},
{
"code" : "status",
"valueCode" : "B"
}
]
},
{
"id" : "3584",
"code" : "206",
"display" : "Application record locked",
"definition" : "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "Datensatz durch Applikation gesperrt"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: The transaction could not be performed at the application storage level, e.g., database locked."
},
{
"code" : "status",
"valueCode" : "B"
}
]
},
{
"id" : "3585",
"code" : "207",
"display" : "Application error",
"definition" : "An application level error has occurred and the detail for that error is identified in ERR-5.",
"designation" : [
{
"language" : "de",
"use" : {
"system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
"code" : "preferredForLanguage"
},
"value" : "applikationsinterner Fehler"
}
],
"property" : [
{
"code" : "v2-concComment",
"valueString" : "This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide."
},
{
"code" : "v2-concCommentAsPub",
"valueString" : "Rejection: A catchall for internal errors not explicitly covered by other codes."
},
{
"code" : "status",
"valueCode" : "A"
}
]
}
]
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.