FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource CodeSystem/FHIR Server from package hl7.terminology#current (47 ms)

Package hl7.terminology
Type CodeSystem
Id Id
FHIR Version R5
Source http://terminology.hl7.org/https://build.fhir.org/ig/HL7/UTG/CodeSystem-v2-0357.html
Url http://terminology.hl7.org/CodeSystem/v2-0357
Version 2.0.0
Status active
Date 2019-12-01
Name MessageErrorCondition
Title messageErrorCondition
Experimental False
Realm uv
Authority hl7
Description HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.
Purpose Underlying Master Code System for V2 table 0357 (Message Error Condition Codes)
Copyright This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html
Content complete
valueSet http://terminology.hl7.org/ValueSet/v2-0357

Resources that use this resource

ValueSet
v2-0357 hl7VS-messageErrorConditionCodes

Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem v2-0357

Properties

This code system defines the following properties for its concepts

NameCodeURITypeDescription
statusstatushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statuscodeStatus of the concept
deprecateddeprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedcodeVersion of HL7 in which the code was deprecated
V2 Concept Commentv2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentstringV2 Concept Comment
V2 Concept Comment As Publishedv2-concCommentAsPubhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPubstringV2 Concept Comment As Published

Concepts

This case-sensitive code system http://terminology.hl7.org/CodeSystem/v2-0357 defines the following codes in a Is-A hierarchy:

CodeDisplayDefinitionV2 Concept CommentV2 Concept Comment As PublishedDeutsch (German, de)
0 Message acceptedMessage acceptedSuccess. Optional, as the AA conveys success. Used for systems that must always return a status code.Success. Optional, as the AA conveys success. Used for systems that must always return a status code.Nachricht akzeptiert
100 Segment sequence errorSegment sequence errorError: The message segments were not in the proper order, or required segments are missing.Error: The message segments were not in the proper order, or required segments are missing.Fehler in der Segmentreihenfolge
101 Required field missingRequired field missingError: A required field is missing from a segmentError: A required field is missing from a segmenterforderliches Feld leer
102 Data type errorData type errorError: The field contained data of the wrong data type, e.g., an NM field contained "FOO".Error: The field contained data of the wrong data type, e.g., an NM field contained "FOO".Datentypfehler
103 Table value not foundTable value not foundError: A field of data type ID or IS was compared against the corresponding table, and no match was found.Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.fehlender Eintrag in der Tabelle
104 Value too longValue too longError: a value exceeded the normative length, or the length that the application is able to safely handle.Error: a value exceeded the normative length, or the length that the application is able to safely handle.
198 Non-Conformant CardinalityAn error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality.Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message.
199 Other HL7 ErrorAny other error with the HL7 syntax that is not captured in any of the other error codes in this set.Error
200 Unsupported message typeUnsupported message typeRejection: The Message Type is not supported.Rejection: The Message Type is not supported.Nachrichtentyp wird nicht unterstützt
201 Unsupported event codeUnsupported event codeRejection: The Event Code is not supported.Rejection: The Event Code is not supported.Ereignis wird nicht unterstützt
202 Unsupported processing idUnsupported processing idRejection: The Processing ID is not supported.Rejection: The Processing ID is not supported.Processing-ID wird nicht unterstützt
203 Unsupported version idUnsupported version idRejection: The Version ID is not supported.Rejection: The Version ID is not supported.Version wird nicht unterstützt
204 Unknown key identifierRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient.Schlüsselwert nicht gefunden
205 Duplicate key identifierRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.).doppelter Schlüsselwert
206 Application record lockedRetained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).Rejection: The transaction could not be performed at the application storage level, e.g., database locked.Datensatz durch Applikation gesperrt
207 Application errorAn application level error has occurred and the detail for that error is identified in ERR-5.This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide.Rejection: A catchall for internal errors not explicitly covered by other codes.applikationsinterner Fehler

Source

{
  "resourceType" : "CodeSystem",
  "id" : "v2-0357",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem v2-0357</b></p><a name=\"v2-0357\"> </a><a name=\"hcv2-0357\"> </a><a name=\"v2-0357-en-US\"> </a><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Name</b></td><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>status</td><td>status</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#status</td><td>code</td><td>Status of the concept</td></tr><tr><td>deprecated</td><td>deprecated</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated</td><td>code</td><td>Version of HL7 in which the code was deprecated</td></tr><tr><td>V2 Concept Comment</td><td>v2-concComment</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment</td><td>string</td><td>V2 Concept Comment</td></tr><tr><td>V2 Concept Comment As Published</td><td>v2-concCommentAsPub</td><td>http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub</td><td>string</td><td>V2 Concept Comment As Published</td></tr></table><p><b>Concepts</b></p><p>This case-sensitive code system <code>http://terminology.hl7.org/CodeSystem/v2-0357</code> defines the following codes in a Is-A hierarchy:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>V2 Concept Comment</b></td><td><b>V2 Concept Comment As Published</b></td><td><b>Deutsch (German, de)</b></td></tr><tr><td style=\"white-space:nowrap\">0<a name=\"v2-0357-0\"> </a></td><td>Message accepted</td><td>Message accepted</td><td>Success. Optional, as the AA conveys success. Used for systems that must always return a status code.</td><td>Success. Optional, as the AA conveys success. Used for systems that must always return a status code.</td><td>Nachricht akzeptiert</td></tr><tr><td style=\"white-space:nowrap\">100<a name=\"v2-0357-100\"> </a></td><td>Segment sequence error</td><td>Segment sequence error</td><td>Error: The message segments were not in the proper order, or required segments are missing.</td><td>Error: The message segments were not in the proper order, or required segments are missing.</td><td>Fehler in der Segmentreihenfolge</td></tr><tr><td style=\"white-space:nowrap\">101<a name=\"v2-0357-101\"> </a></td><td>Required field missing</td><td>Required field missing</td><td>Error: A required field is missing from a segment</td><td>Error: A required field is missing from a segment</td><td>erforderliches Feld leer</td></tr><tr><td style=\"white-space:nowrap\">102<a name=\"v2-0357-102\"> </a></td><td>Data type error</td><td>Data type error</td><td>Error: The field contained data of the wrong data type, e.g., an NM field contained &quot;FOO&quot;.</td><td>Error: The field contained data of the wrong data type, e.g., an NM field contained &quot;FOO&quot;.</td><td>Datentypfehler</td></tr><tr><td style=\"white-space:nowrap\">103<a name=\"v2-0357-103\"> </a></td><td>Table value not found</td><td>Table value not found</td><td>Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.</td><td>Error: A field of data type ID or IS was compared against the corresponding table, and no match was found.</td><td>fehlender Eintrag in der Tabelle</td></tr><tr><td style=\"white-space:nowrap\">104<a name=\"v2-0357-104\"> </a></td><td>Value too long</td><td>Value too long</td><td>Error: a value exceeded the normative length, or the length that the application is able to safely handle.</td><td>Error: a value exceeded the normative length, or the length that the application is able to safely handle.</td><td/></tr><tr><td style=\"white-space:nowrap\">198<a name=\"v2-0357-198\"> </a></td><td>Non-Conformant Cardinality</td><td>An error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality.</td><td>Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message.</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">199<a name=\"v2-0357-199\"> </a></td><td>Other HL7 Error</td><td>Any other error with the HL7 syntax that is not captured in any of the other error codes in this set.</td><td>Error</td><td/><td/></tr><tr><td style=\"white-space:nowrap\">200<a name=\"v2-0357-200\"> </a></td><td>Unsupported message type</td><td>Unsupported message type</td><td>Rejection: The Message Type is not supported.</td><td>Rejection: The Message Type is not supported.</td><td>Nachrichtentyp wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">201<a name=\"v2-0357-201\"> </a></td><td>Unsupported event code</td><td>Unsupported event code</td><td>Rejection: The Event Code is not supported.</td><td>Rejection: The Event Code is not supported.</td><td>Ereignis wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">202<a name=\"v2-0357-202\"> </a></td><td>Unsupported processing id</td><td>Unsupported processing id</td><td>Rejection: The Processing ID is not supported.</td><td>Rejection: The Processing ID is not supported.</td><td>Processing-ID wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">203<a name=\"v2-0357-203\"> </a></td><td>Unsupported version id</td><td>Unsupported version id</td><td>Rejection: The Version ID is not supported.</td><td>Rejection: The Version ID is not supported.</td><td>Version wird nicht unterstützt</td></tr><tr><td style=\"white-space:nowrap\">204<a name=\"v2-0357-204\"> </a></td><td>Unknown key identifier</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient.</td><td>Schlüsselwert nicht gefunden</td></tr><tr><td style=\"white-space:nowrap\">205<a name=\"v2-0357-205\"> </a></td><td>Duplicate key identifier</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.).</td><td>doppelter Schlüsselwert</td></tr><tr><td style=\"white-space:nowrap\">206<a name=\"v2-0357-206\"> </a></td><td>Application record locked</td><td>Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.</td><td>ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code).</td><td>Rejection: The transaction could not be performed at the application storage level, e.g., database locked.</td><td>Datensatz durch Applikation gesperrt</td></tr><tr><td style=\"white-space:nowrap\">207<a name=\"v2-0357-207\"> </a></td><td>Application error</td><td>An application level error has occurred and the detail for that error is identified in ERR-5.</td><td>This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide.</td><td>Rejection: A catchall for internal errors not explicitly covered by other codes.</td><td>applikationsinterner Fehler</td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "inm"
    }
  ],
  "url" : "http://terminology.hl7.org/CodeSystem/v2-0357",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.18.217"
    }
  ],
  "version" : "2.0.0",
  "name" : "MessageErrorCondition",
  "title" : "messageErrorCondition",
  "status" : "active",
  "experimental" : false,
  "date" : "2019-12-01",
  "publisher" : "Health Level Seven International",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://hl7.org"
        },
        {
          "system" : "email",
          "value" : "hq@HL7.org"
        }
      ]
    }
  ],
  "description" : "HL7-defined code system of concepts specifying the HL7 (communications) error code. Used in the ERR segment in HL7 Version 2.x messaging.",
  "purpose" : "Underlying Master Code System for V2 table 0357 (Message Error Condition Codes)",
  "copyright" : "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html",
  "caseSensitive" : true,
  "valueSet" : "http://terminology.hl7.org/ValueSet/v2-0357",
  "hierarchyMeaning" : "is-a",
  "compositional" : false,
  "versionNeeded" : false,
  "content" : "complete",
  "property" : [
    {
      "code" : "status",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
      "description" : "Status of the concept",
      "type" : "code"
    },
    {
      "code" : "deprecated",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
      "description" : "Version of HL7 in which the code was deprecated",
      "type" : "code"
    },
    {
      "code" : "v2-concComment",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment",
      "description" : "V2 Concept Comment",
      "type" : "string"
    },
    {
      "code" : "v2-concCommentAsPub",
      "uri" : "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub",
      "description" : "V2 Concept Comment As Published",
      "type" : "string"
    }
  ],
  "concept" : [
    {
      "id" : "3570",
      "code" : "0",
      "display" : "Message accepted",
      "definition" : "Message accepted",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Nachricht akzeptiert"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Success. Optional, as the AA conveys success. Used for systems that must always return a status code."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Success. Optional, as the AA conveys success. Used for systems that must always return a status code."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3571",
      "code" : "100",
      "display" : "Segment sequence error",
      "definition" : "Segment sequence error",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Fehler in der Segmentreihenfolge"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error: The message segments were not in the proper order, or required segments are missing."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Error: The message segments were not in the proper order, or required segments are missing."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3572",
      "code" : "101",
      "display" : "Required field missing",
      "definition" : "Required field missing",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "erforderliches Feld leer"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error: A required field is missing from a segment"
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Error: A required field is missing from a segment"
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3573",
      "code" : "102",
      "display" : "Data type error",
      "definition" : "Data type error",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Datentypfehler"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error: The field contained data of the wrong data type, e.g., an NM field contained \"FOO\"."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Error: The field contained data of the wrong data type, e.g., an NM field contained \"FOO\"."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3574",
      "code" : "103",
      "display" : "Table value not found",
      "definition" : "Table value not found",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "fehlender Eintrag in der Tabelle"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Error: A field of data type ID or IS was compared against the corresponding table, and no match was found."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3575",
      "code" : "104",
      "display" : "Value too long",
      "definition" : "Value too long",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error: a value exceeded the normative length, or the length that the application is able to safely handle."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Error: a value exceeded the normative length, or the length that the application is able to safely handle."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3576",
      "code" : "198",
      "display" : "Non-Conformant Cardinality",
      "definition" : "An error has been encountered related to HL7 message content. Message is not -conformant with the applicable specification’s (base standard, conformance profile or implementation profile) cardinality.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error: Cardinality is listed as [0..3] and more than 3 of the identified element are present in the message."
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "3577",
      "code" : "199",
      "display" : "Other HL7 Error",
      "definition" : "Any other error with the HL7 syntax that is not captured in any of the other error codes in this set.",
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Error"
        },
        {
          "code" : "status",
          "valueCode" : "N"
        }
      ]
    },
    {
      "id" : "3578",
      "code" : "200",
      "display" : "Unsupported message type",
      "definition" : "Unsupported message type",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Nachrichtentyp wird nicht unterstützt"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Rejection: The Message Type is not supported."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The Message Type is not supported."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3579",
      "code" : "201",
      "display" : "Unsupported event code",
      "definition" : "Unsupported event code",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Ereignis wird nicht unterstützt"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Rejection: The Event Code is not supported."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The Event Code is not supported."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3580",
      "code" : "202",
      "display" : "Unsupported processing id",
      "definition" : "Unsupported processing id",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Processing-ID wird nicht unterstützt"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Rejection: The Processing ID is not supported."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The Processing ID is not supported."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3581",
      "code" : "203",
      "display" : "Unsupported version id",
      "definition" : "Unsupported version id",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Version wird nicht unterstützt"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "Rejection: The Version ID is not supported."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The Version ID is not supported."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    },
    {
      "id" : "3582",
      "code" : "204",
      "display" : "Unknown key identifier",
      "definition" : "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 101 (Unknown Key Identifier) from code system HL70533.",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Schlüsselwert nicht gefunden"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The ID of the patient, order, etc., was not found. Used for transactions other than additions, e.g., transfer of a non-existent patient."
        },
        {
          "code" : "status",
          "valueCode" : "B"
        }
      ]
    },
    {
      "id" : "3583",
      "code" : "205",
      "display" : "Duplicate key identifier",
      "definition" : "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 102 (Duplicate Key Identifier) from code system HL70533.",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "doppelter Schlüsselwert"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The ID of the patient, order, etc., already exists. Used in response to addition transactions (Admit, New Order, etc.)."
        },
        {
          "code" : "status",
          "valueCode" : "B"
        }
      ]
    },
    {
      "id" : "3584",
      "code" : "206",
      "display" : "Application record locked",
      "definition" : "Retained for backwards compatibility only: This situation should be reported in ERR-5 (Application Error Code) using code 103 (Application record locked) from code system HL70533.",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "Datensatz durch Applikation gesperrt"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "ERR-3 (HL7 Error Code) should be used to convey errors at the structural level and this is an application level error, which should be reported in ERR-5 (Application Error Code)."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: The transaction could not be performed at the application storage level, e.g., database locked."
        },
        {
          "code" : "status",
          "valueCode" : "B"
        }
      ]
    },
    {
      "id" : "3585",
      "code" : "207",
      "display" : "Application error",
      "definition" : "An application level error has occurred and the detail for that error is identified in ERR-5.",
      "designation" : [
        {
          "language" : "de",
          "use" : {
            "system" : "http://terminology.hl7.org/CodeSystem/hl7TermMaintInfra",
            "code" : "preferredForLanguage"
          },
          "value" : "applikationsinterner Fehler"
        }
      ],
      "property" : [
        {
          "code" : "v2-concComment",
          "valueString" : "This value is used when no other value in this list is applicable and there is an application error reported in ERR-5. It is applicable when ERR-3 is required in an implementation guide."
        },
        {
          "code" : "v2-concCommentAsPub",
          "valueString" : "Rejection: A catchall for internal errors not explicitly covered by other codes."
        },
        {
          "code" : "status",
          "valueCode" : "A"
        }
      ]
    }
  ]
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.